Jual Elisa StatFax 2100& WASHER 2600
Features: STAT FAX 2100 MICROPLATE READER
- Fully automatic.
- Bichromatic optics
- On board data reduction calculations include regressions, curve fitting, and cutoff absorbance calculations with step-by-step user prompting.
- Includes parallel and serial outputs.
- Large, non-volatile memory stores at least 50 user entered tests.
Photometric
Linear Measurement Range: - 0.20 to 3.0 Absorbance Units (A)
Photometric Accuracy: 1% or better
Stability: Drift of no more than 0.005A in 8 hours
Light Source: Tungsten lamp, with lamp saver feature
Wavelengths: Standard - 405, 450, 492, and 630nm
6-VIS - 405, 450, 492, 545, 600, and 630nm
6-UV - 340, 405, 450, 492, 545, and 630nm
Type of Filter: Multiple-cavity hard coat interference, 10nm half bandpass
Vessel: Standard 96-well microtiter plates or strip trays
Electronics
Display: Two-line LCD, alphanumeric, 24 characters per line
Printer Requirements: Parallel or serial, 80 column, 2K byte minimum
buffer capacity, EPSON compatible
Keyboard: 29-key, domed membrane switch, enunciating
Power Requirements: 115V/230V, 50/60Hz (switch selectable)
Serial Port: 2400 baud, 1 start bit, 8 data, 1 stop, no parity
Microprocessor: Z80A or Z180
Non-Volatile Memory: Battery supported RAM, holds approx. 50 tests and curves
Software
Speed: Reads and prints absorbances of 96 wells in about 2 minutes
Calculation Modes: Single-point calibration, uptake mode, point to point
curve fit, polynomial regression, linear regression (log
& linear), cutoff absorbance, multipoint % absorbance
Additional Features: Complete user prompting, flags and error messages,
partial plate reading, alphanumeric test naming, auto-
matic interpretation options, duplicate options, clock
and calendar, controls locator, self-check system, curve
plotting and editing
Other
Mixer: Variable time, fixed speed
Enclosure: Fire-retardant ABS plastic cover with metal base
Dimensions: 17 x 14.5 x 7
Weight: 30lbs.
Certifications: UL Listed, CE Mark available
Stat Fax®2600
|
Residual Volume | <3ul |
Processing Time
(Full Plate) | 55 seconds aspirate/dispense
(8 Probe Wash Head Standard (12 or 16 Probe Wash Heads Available) |
Dispense Accuracy | < 3% CV at 300 ul |
Liquid Contact Materials | Stainless steel, Delrin, silicone, nylon, PVC, polypropylene |
Display | Two-line LCD, alphanumeric, 24 characters per line |
Washing Programs | Aspirate, dispense, soak - up to 99 minutes 99 seconds |
Non-Volatile Memory | Battery supported RAM, holds approx. 50 wash protocols |
Keyboard | 16-key, domed membrane switch, 4 x 4, enunciating |
Microproccssor | Z80A or Z180 |
Power Requirements | 115V, 50-60Hz (switch selectable) |
Bottles | Plastic, Wash and Waste (2L), Rinse (1L) |
Enclosure | Fire-retardant ABS plastic cover with metal base |
Dimensions | 39 x 34 x 19 cm, 8.6 kg |
Certifications | NRTL Listed、CE Mark |
Special Menu Options | Auto Alignment - senses physical geometry of the head, plate, and carrier mechanism
Standby-disables pumps and releases vacuum and pressure
Self-Check-performs internal performance tests alignment
Auxiliary-allows selection of pre-programmed tests, mechanism
and volume calibration, and alphanumeric test naming
Constant Plate Cycle Time
Optional Manual Plate Depth Selection |
Certifications | NRTL Listed, CE Mark |
STATFAX2100 MICROPLATE READER
harga 1set lengkap.Reader& WASHER
Garansi 1 tahun buatan America
PT.CAHAYA RESTU PRATAMA
cibitung Bekasi
Hp : 081380398896